AKZS950/..G-10.16 及绿色

  • 2 to 9 poles
  • Lift type
  • Wire entry vertical to plugging direction
  • Coding with coding star
  • For snapping onto TS 32/35
  • PCB terminal block with pin strip
线径
Solid 0.2 mm² - 4.0 mm²
Stranded (flexible) 0.2 mm² - 2.5 mm²
Stranded with ferrule 0.25 mm² - 2.5 mm²
Dimensions
Stripped length 6.0 mm
Materials
Clamp 黄铜
Screw 钢铁
Contact tag 铜合金
Insulating Material
Material PA 6.6
Flammability class UL 94 V-0
Temperatures
Operating temperature -40 °C (without mech. load) - 105 °C
Store temperature -40 °C - 105 °C
波峰焊工艺 回流工艺
- -
Peak soldering time, recommended - -
Colours
GREEN, RAL 6018
 
LIGHT GREEN, similar RAL 6018
 
Number of Poles Width (mm) 物品名称 货号 PU
2
16.76 AKZS950/2G-10.16 及绿色 50950027031E 100
3
26.92 AKZS950/3G-10.16 及绿色 50950037031E 100
4
37.08 AKZS950/4G-10.16 及绿色 50950047031D 50
5
47.24 AKZS950/5G-10.16 及绿色 50950057031D 50
6
57.40 AKZS950/6G-10.16 及绿色 50950067031D 50
7
67.56 AKZS950/7G-10.16 及绿色 50950077031D 50
8
77.72 AKZS950/8G-10.16 及绿色 50950087031D 50
9
87.88 AKZS950/9G-10.16 及绿色 50950097031D 50

Please select one of the above listed number of poles before you order for quotation or samples.

to Inquiry Form
Coding Star CS2-5.0/5.08-RED

Coding Star CS2-5.0/5.08-RED
50000000024

Separating Element SE-STL950-GREEN

Separating Element SE-STL950-GREEN
50950000002

Mounting Rail Clip CLP-AKZS950-TS15/TS35

Mounting Rail Clip CLP-AKZS950-TS15/TS35
50950000005

Mounting Rail Clip CLP-AKZS950-TS32/TS35

Mounting Rail Clip CLP-AKZS950-TS32/TS35
50950000006

Ratings
UseGroup B C D      
Rated voltage 300 V 150 V 300 V 250 V  
Rated current 15 A 15 A - 12 A  
Overvoltage category       III  
Rated wire size       min max
- solid AWG 28-12 AWG 28-12 AWG 28-12 0.5 mm² (5 A) 2.5 mm² (12 A)
- stranded - - - - -
- stranded (flexible) AWG 28-12 AWG 28-12 AWG 28-12 0.5 mm² (5 A) 2.5 mm² (12 A)
Torque 0.45 Nm 0.45 Nm 0.45 Nm 0.50 Nm  
Screw size M3 M3 M3 M3  
Test voltage 1.60 kV 1.30 kV 1.60 kV 4.0 kV  
Pollution degree       3  
In combination of connectors with different admission data, the lower value is valid.