PTR Hartmann

AKZ4961/..KD-7.62-BASALTGREY
New

  • 2 to 12 poles
  • Push-In connection
  • Spacing 7.62 mm
  • Wire entry parallel to plugging direction
  • Coding with coding star
  • Lever for easy opening of clamping point
  • Test jack on every clamping point
  • With snap-in hooks to snap onto the pin strip
Wire Size
Solid 0.2 mm² - 2.5 mm²
Stranded (flexible) 0.2 mm² - 2.5 mm²
Stranded with ferrule 0.25 mm² - 2.5 mm²
Dimensions
Stripped length 12.0 mm
Materials
Contact spring Copper Alloy
Clamp spring Stainless Steel
Insulating Material
Material PA 6.6
Flammability class UL 94 V-0
Temperatures
Operating temperature -40 °C (without mech. load) - 105 °C
Store temperature -40 °C - 105 °C
Wave Soldering Process Reflow Process
Soldering temperature, recommended - -
Peak soldering time, recommended - -
Colours
BASALT GREY, RAL 7012
 
GREEN, RAL 6018
 
LIGHT GREEN, similar RAL 6018
 
Number of Poles Width (mm) Article Designation Article Number PU
2
13.32 AKZ4961/2KD-7.62-BASALTGREY 54961020421D 50
3
20.94 AKZ4961/3KD-7.62-BASALTGREY 54961030421D 50
4
28.56 AKZ4961/4KD-7.62-BASALTGREY 54961040421D 50
5
36.18 AKZ4961/5KD-7.62-BASALTGREY 54961050421D 50
6
43.80 AKZ4961/6KD-7.62-BASALTGREY 54961060421D 50
7
51.42 AKZ4961/7KD-7.62-BASALTGREY 54961070421D 50
8
59.04 AKZ4961/8KD-7.62-BASALTGREY 54961080421D 50
9
66.66 AKZ4961/9KD-7.62-BASALTGREY 54961090421D 50
10
74.28 AKZ4961/10KD-7.62-BASALTGREY 54961100421D 50
11
81.90 AKZ4961/11KD-7.62-BASALTGREY 54961110421D 50
12
89.52 AKZ4961/12KD-7.62-BASALTGREY 54961120421D 50

Please select one of the above listed number of poles before you order for quotation or samples.

to Inquiry Form
Coding Star CS1-5.0/5.08-RED

Coding Star CS1-5.0/5.08-RED
Article Number50000000021

Ratings
UseGroup B C D      
Rated voltage 300 V - 300 V 400 V  
Rated current 10 A - 10 A 12 A  
Overvoltage category       III  
Rated wire size       min max
- solid AWG 26-12 - AWG 26-12 0.2 mm² 2.5 mm²
- stranded - - - - -
- stranded (flexible) AWG 26-12 - AWG 26-12 0.2 mm² 2.5 mm²
Test voltage 1.60 kV - 1.60 kV 6.0 kV  
Pollution degree       3  
In combination of connectors with different admission data, the lower value is valid.