PTR Hartmann

AK4101/..KD-10.0-PEBBLE GREY

  • 2 to n poles
  • 1 pole module
  • Push-In connection
  • Spacing 10.0 mm
  • Wire entry parallel to PCB
  • With lever
  • With two soldering pins
Wire Size
Solid 0.08 mm² - 2.5 mm²
Stranded (flexible) 0.5 mm² - 1.5 mm²
Stranded with ferrule 0.14 mm² - 1.0 mm²
Dimensions
Stripped length 9.0 mm
PCB hole diameter 1.0 mm
Materials
Solder tab Copper Alloy
Clamp spring Stainless Steel
Insulating Material
Material PA 6.6
Flammability class UL 94 V-0
Temperatures
Operating temperature -40 °C (without mech. load) - 105 °C
Store temperature -40 °C - 105 °C
Wave Soldering Process Reflow Process
Soldering temperature, recommended 260 °C -
Peak soldering time, recommended 3-4 s -
Colours
PEBBLE GREY, RAL 7032
 
BLUE, RAL 5015
 
Number of Poles Width (mm) Article Designation Article Number PU
2
16.60 AK4101/2KD-10.0-PEBBLE GREY 54101020021F 200
3
26.60 AK4101/3KD-10.0-PEBBLE GREY 54101030021F 200
4
36.60 AK4101/4KD-10.0-PEBBLE GREY 54101040021E 100
5
46.60 AK4101/5KD-10.0-PEBBLE GREY 54101050021E 100
6
56.60 AK4101/6KD-10.0-PEBBLE GREY 54101060021D 50
7
66.60 AK4101/7KD-10.0-PEBBLE GREY 54101070021D 50
8
76.60 AK4101/8KD-10.0-PEBBLE GREY 54101080021D 50
9
86.60 AK4101/9KD-10.0-PEBBLE GREY 54101090021D 50
10
96.60 AK4101/10KD-10.0-PEBBLE GREY 54101100021D 50
11
106.60 AK4101/11KD-10.0-PEBBLE GREY 54101110021D 50
12
116.60 AK4101/12KD-10.0-PEBBLE GREY 54101120021D 50

Please select one of the above listed number of poles before you order for quotation or samples.

to Inquiry Form
Bridge, 2-pole, insulated, BRI/2-5.0/5.08-LIGHT GREY

Bridge, 2-pole, insulated, BRI/2-5.0/5.08-LIGHT GREY
Article Number50000000006

Bridge, 3-pole, insulated, BRI/3-5.0/5.08-LIGHT GREY

Bridge, 3-pole, insulated, BRI/3-5.0/5.08-LIGHT GREY
Article Number50000000007

Ratings **
UseGroup B C D      
Rated voltage 300 V - 300 V 250 V  
Rated current 10 A - 10 A 17.5 A  
Rated wire size       min max
- solid AWG 20-14 - AWG 20-14 0.5 mm² 2.5 mm²
- stranded - - - - -
- stranded (flexible) - - - - -
Test voltage 1.60 kV - 1.60 kV 2.0 kV  
** Data similar to EN 60998