STLZ1590/..G-3.81-GREEN

  • 2 to 20 poles
  • 45° pin strip
  • Spacing 3.81 mm
  • Closed ends
  • Spacing 7.62 mm also available
Wire Size
Solid - -
Stranded (flexible) - -
Stranded with ferrule - -
Dimensions
PCB hole diameter 1.2 mm
Materials
Contact pin Copper Alloy
Insulating Material
Material PBT
Flammability class UL 94 V-0
Temperatures
Operating temperature -40 °C (without mech. load) - 105 °C
Store temperature -40 °C - 105 °C
Wave Soldering Process Reflow Process
Soldering temperature, recommended 260 °C -
Peak soldering time, recommended 3-4 s -
Colours
GREEN, RAL 6018
 
LIGHT GREEN, similar RAL 6018
 
Number of Poles Width (mm) Article Designation Article Number PU
2
9.01 STLZ1590/2G-3.81-GREEN 51590025121F 200
3
12.82 STLZ1590/3G-3.81-GREEN 51590035121F 200
4
16.63 STLZ1590/4G-3.81-GREEN 51590045121F 200
5
20.44 STLZ1590/5G-3.81-GREEN 51590055121F 200
6
24.25 STLZ1590/6G-3.81-GREEN 51590065121E 100
7
28.06 STLZ1590/7G-3.81-GREEN 51590075121E 100
8
31.87 STLZ1590/8G-3.81-GREEN 51590085121D 50
9
35.68 STLZ1590/9G-3.81-GREEN 51590095121D 50
10
39.49 STLZ1590/10G-3.81-GREEN 51590105121D 50
11
43.30 STLZ1590/11G-3.81-GREEN 51590115121D 50
12
47.11 STLZ1590/12G-3.81-GREEN 51590125121D 50
13
50.92 STLZ1590/13G-3.81-GREEN 51590135121D 50
14
54.73 STLZ1590/14G-3.81-GREEN 51590145121D 50
15
58.54 STLZ1590/15G-3.81-GREEN 51590155121D 50
16
62.35 STLZ1590/16G-3.81-GREEN 51590165121D 50
17
66.16 STLZ1590/17G-3.81-GREEN 51590175121D 50
18
69.97 STLZ1590/18G-3.81-GREEN 51590185121D 50
19
73.78 STLZ1590/19G-3.81-GREEN 51590195121D 50
20
77.59 STLZ1590/20G-3.81-GREEN 51590205121D 50

Please select one of the above listed number of poles before you order for quotation or samples.

to Inquiry Form
Coding Star CS1-3.5/3.81-RED

Coding Star CS1-3.5/3.81-RED
Article Number50000000023

Separating Element SE-STL1550-GREEN

Separating Element SE-STL1550-GREEN
Article Number51550000002

Ratings
UseGroup B C D      
Rated voltage 300 V - 300 V 160 V  
Rated current 10 A - 10 A 10 A  
Overvoltage category       III  
Test voltage 1.60 kV - 1.60 kV 2.5 kV  
Pollution degree       3  