1105
Switching Test Probe "Opener" (NC) with Easy-Replacement System 138 mil / 3.5 mm - Switching Travel 1.7 mm
Series 3011/2FGS
0
- Test Probe with switching function for cable harness test and presence verification
- Easy-replacement system (replacement without soldering)
- Switching test probe "Opener" (NC) type
- Variable extention height
- High soldering temperature up to 300°C
| Mechanical Data | | |
| Center | 4.00 mm /160 mil |
| Full travel | 5.00 mm |
| Working travel | 4.00 mm |
| Switching travel | 1.70 mm |
| Pre-loaded spring force | 0.12/ 0.25/ 0.30/ 0.40/ 0.60/ 1.80/ 1.40/ 1.70/ 2.00/ 2.70/ 2.00/ 5.00/ 4.00 N |
| Spring force at working travel | 0.75/ 1.25/ 1.80/ 2.30/ 3.50/ 6.50/ 7.00/ 8.50/ 9.00/ 9.50/ 10.00/ 12.50/ 13.00 N |
| Spring force at switching travel | 0.20/ 0.45/ 0.75/ 1.00/ 1.60/ 3.60/ 3.60/ 4.40/ 4.80/ 5.40/ 5.20/ 8.00/ 7.60 N |
| Temperature range | -30 °C - +120 °C |
| Electrical Data | | |
| Receptacle-Plunger |
| Continuous current | 5.0 A |
| Typical continuity resistance | ≤ 15 mOhm |
| Pin-Plunger |
| Continuous current | 1.0 A |
| Typical continuity resistance | ≤ 50 mOhm |
| Materials | | |
| Barrel | Brass, gold-plated |
| Plunger | Steel | |
| Receptacle | Brass, gold-plated |
| Recommended diameter of drill | | |
| H 3011/GWR5 (/R /RK) |
| HP 2361.1 / EP CP 201 (trolitax) | 3.02 mm |
| HGW 2372 (glass filled material) | 3.04 mm |
| H 3011/K (/5K) |
| HP 2361.1 / EP CP 201 (trolitax) | 3.01 mm |
| HGW 2372 (glass filled material) | 3.02 mm |
| Available Screw Tools | | |
| Article Designation | Max. Plate Diameter |
Tip Style • Diameter • Plating
| 3011/ | 2 | F | G | S | - | C | - | 1.8 N | - | Au | - | 2.3 |
| [1] | [2] | [3] | [4] | [5] | | [6] | | [7] | | [8] | | [9] |
- Series
- Collar Height
- Type "Opener" (NC)
- Threaded Design
- Plug-in Connector
- Tip Style
- Spring Force
- Tip Plating
- Tip Diameter